1. HOME
  2. Product information
  3. Thermal control equipment Control Panel Cooling unit ENC Series
  4. Control panel cooling unit Product lineup
  5. ENC-AR1120EX-SUS-2

Control panel cooling unit ENC-AR1120EX-SUS-2

Control Panel Cooling unit
Freon-gas Special specifications
Top-mounting

ENC-AR1120EX-SUS-2

ENC Series

Control Panel Cooling unit Freon-gas Special specifications ENC-AR1120EX-SUS-2

Stainless steel panel cooler to realize a high durability.

  • Freon-gas
  • Special specifications
Cooling capacity(W) 950/1100
Rated Voltage(V) Single-phase 200V AC
Mounting type Top-mounting
External dimensions(mm) H318×W600×D353
Weight(kg) 28

Product Details for ENC-AR1120EX-SUS-2

Specifications

(50/60Hz)

Mounting type Top-mounting
Cooling capacity(W) 950/1100
Setting temperature range(℃) 25 to 45
Ambient Temperature(℃) 20 to 50
Ambient Humidity(%RH) 10~85 (No condensation)
Dimensions(mm) H318×W600×D353
Weight(kg) 28
Coating Color NSSC 180-HL Finish
Rated voltage(V) Single-phase 200V AC
Current consumption : Rating(A) 2.7/2.4
Current consumption : Max(A) 3.2/3.3
Starting Current(A) 7.5/7.1
Power consumption : Rating(W) 440/470
Power consumption : Max(W) 570/630
Noise Resistance LEVEL4 by Fast Transient / Burst Immunity Test
Vibration resistance Equivalent to JIS Z 0200 Level1
Dustproof and splashproof protection grade Equivalent to IP54 (internal circulation route)
Certification
Refrigerant / Amount(g) R134a 240g
Noise (dB (A)) Approx. 60/65
External output Cooling operation output/Alarm output (No-voltage/normal open: resistive load 250V 2A)
Display Internal temperature/LED/RUN LED

Note)
Cooling capacity : Rated capacity value when external temperature is 35°C, internal setting temperature is 35°C. (measurement conditions:JIS-C-9612 air enthalpy method))
Use area temperature / humidity : Use area temperature / humidity is not meant to satisfy all conditions in temperature and humidity.
Rating Value : 35°C ambient temperature, ambient humidity RH 40%.
MAX value: use area temperature at the maximum use area temperature allowed, use area humidity of 40%RH.
Use area temperature: If the outside air temperature is 0 ° C or lower, set the temperature internal to 30 ° C or higher.
Use the product keeping the use power supply and voltage; within ±10% of rated power supply and rated voltage.
Reading an instruction manual well certainly before use and please use it right.

External dimensions

ENC-AR1120EX-SUS-2 External dimensions

NC-AR1120EX-SUS-2
(1) Power line : Cord length 3m
(2) Alarm Output Line : Cord length 3m

Diagram of Panel Cutout

ENC-AR1120EX-SUS-2 Diagram of Panel Cutout

Capacity characteristic chart

ENC-AR1120EX-SUS-2 Capacity characteristic chart

*Contact our sales representative if you are using the control panel cooler in an environment close to the permissible ambient temperature upper limit.

[Caution]
To ensure proper operation of this equipment, read the operation manual before use.
Product is delivered by truck. (To a designated location in Japan *Island destinations excluded)
Depending on model and quantity, separate charter delivery may be arranged (additional costs apply). 
When delivering overseas, special packing for overseas shipment is recommended.
After checking the specifications of the FA cooler, be sure to insert an appropriate breaker (circuit breaker for wiring) between the FA cooler and the power supply.
Using beyond the rated power supply range may cause malfunction.
Perform periodic maintenance.
Neglecting periodic maintenance can degrade unit performance and cause mechanical problems.
Do not allow the FA cooler to operate continuously in winter when the outdoor temperature is low.
When disposing of this unit, do so properly in accordance with laws and regulation.