Control panel cooling unit ENC-GR1000EX-Pro

Control Panel Cooling unit
Non-freon-gas Filter-less & Energy saving
Top-mounting

ENC-GR1000EX-Pro

ENC Series

CE ETL CCC
Control Panel Cooling unit Non-freon-gas Filter-less & Energy saving ENC-GR1000EX-Pro
  • Non-freon-gas
  • Filter-less & Energy saving
Cooling capacity(W) 1000
Rated Voltage(V) Single-phase 200 to 240V AC
Mounting type Top-mounting
External dimensions(mm) H348×W600×D353
Weight(kg) Approx. 25

Product Details for ENC-GR1000EX-Pro

Specifications

(50/60Hz)

Mounting type Top-mounting
Cooling capacity(W) 1000
Setting temperature range(℃) 25 to 45
Ambient Temperature(℃) 20 to 55
Ambient Humidity(%RH) 10~85 (No condensation)
Dimensions(mm) H348×W600×D353
Weight(kg) Approx. 25
Coating Color Equivalent color of light beige 5Y 7/1
Rated voltage(V) Single-phase 200 to 240V AC
Current consumption : Rating(A) 3.5
Power consumption : Rating(W) 580
Recommended breaker capacity (A) 10
Vibration resistance JIS Z0200 Level1
Dustproof and splashproof protection grade Equivalent to IP54 (internal circulation route)
Certification CE / ETL / CCC
Refrigerant / Amount(g) R1234yf 310g
Noise (dB (A)) Approx. 71
External output No voltage, normally open: 250V AC and 2A / 30V DC and 2A resistive load
Display Internal temperature/Error/RUN

Cooling Capacity : Rated capacity value when ambient temperat ure is 35°C and ambient humidity is 40%RH, power voltage : 200V. (Test method :JIS B 8615-1 the inside of a air enthalpy test method)
Use area temperature / humidity : Use area temperature / humidity is not meant to satisfy all conditions in temperature and humidity.
Dust prevention / dust proof protection class : Excluding drain port section.
Reading an instruction manual well certainly before use and please use it right.

External dimensions

ENC-GR1000EX-Pro External dimensions

Warning output and external communication cables are optional.
Warning output cable:OP-ENCPR-OTR003
External communication cable:OP-ENCPR-OTR004

Diagram of Panel Cutout

ENC-GR1000EX-Pro Diagram of Panel Cutout

Capacity characteristic chart

ENC-GR1000EX-Pro Capacity characteristic chart

*Contact our sales representative if you are using the control panel cooler in an environment close to the permissible ambient temperature upper limit.

[Caution]
Please use it properly Read the manual before using Delivery of the items will be passed on the car.
(Domestic location specified, except islands) will be (additional cost) Charter flights handled separately by the number, type .
Overseas at the time of delivery, we recommend packing for overseas separately.
Please check through the cooler between the FA and the power (circuit breakers) to the appropriate specification of the FA breaker cooler.
Cause of failure and be used at the rated power supply out of range.
Please use the service and maintenance on a regular basis.
Failure to maintain regular maintenance, you may be a factor in product performance degradation trouble.
When the outside temperature is low in winter, please do not let the FA cooler continuous operation.
When disposing of this product, you should comply with various laws and regulations, please go to the appropriate.