Control panel cooling unit ENC-AS1000HDS-DC
Control Panel Cooling unit
Freon-gas Outdoor specification
Side-mounting
ENC-AS1000HDS-DC
ENC Series

- Freon-gas
- Outdoor specification
Cooling capacity(W) | 1050 |
---|---|
Rated Voltage(V) | 48V DC(40 to 59V DC) |
Mounting type | Side-mounting |
External dimensions(mm) | H1050×W420×D220 |
Weight(kg) | Approx. 30 |
Product Details for ENC-AS1000HDS-DC
Specifications
(50/60Hz)
Mounting type | Side-mounting |
---|---|
Cooling capacity(W) *1 | 1050 |
Setting temperature range(℃) | 25 to 50 |
Ambient Temperature(℃) *2 | -10 to 45 |
Ambient Humidity(%RH) *2 | 95 or lower (No condensation) |
Dimensions(mm) *3 | H1050×W420×D220 |
Weight(kg) | Approx. 30 |
Surface finish | Light beige equivalent (Munsell 5Y7/1 or similar) |
Rated voltage(V) | 48V DC(40 to 59V DC) |
Current consumption : Rating(A) *1 | 4.95 |
Starting Current(A) | 4 |
Power consumption : Rating(W) | 268 |
Recommended breaker capacity (A) | 15 |
Dustproof and splashproof protection grade *4 | IP55 equivalent (internal circulation path) |
Refrigerant / Amount(g) | R134a 370g |
Noise (dB (A)) *5 | Approx. 45 |
External output | Alarm output (no voltage, normally open: 250 V AC and 2 A / 30 V DC and 2 A resistive load) |
Display | Panel internal temperature / Error code / RUN |
*1 The rated value at 35℃ ambient/panel internal temperature and rated voltage.
*2 The ambient temperature and ambient humidity define the operating range and do not guarantee the rated performance.
*3 Excluding protrusions.
*4 Performance based on tests conducted in accordance with JIS C 0920. With the drain port blocked.
*5 The average value measured at a horizontal distance of 1 m from the front, left, and right sides of the product and at the height of the center of the product.
*6 The value in parentheses ( ) is the noise level at low-noise operation. Low-noise operation is activated automatically when the ambient temperature is at 30℃ or below
External dimensions
Diagram of Panel Cutout
Capacity characteristic chart
*Contact our sales representative if you are using the control panel cooler in an environment close to the permissible ambient temperature upper limit.
[Caution]
To ensure proper operation of this equipment, read the operation manual before use.
Product is delivered by truck. (To a designated location in Japan *Island destinations excluded)
Depending on model and quantity, separate charter delivery may be arranged (additional costs apply).
When delivering overseas, special packing for overseas shipment is recommended.
After checking the specifications of the FA cooler, be sure to insert an appropriate breaker (circuit breaker for wiring) between the FA cooler and the power supply.
Using beyond the rated power supply range may cause malfunction.
Perform periodic maintenance.
Neglecting periodic maintenance can degrade unit performance and cause mechanical problems.
Do not allow the FA cooler to operate continuously in winter when the outdoor temperature is low.
When disposing of this unit, do so properly in accordance with laws and regulation.