AC100V to 200V type. Electronic cooler that can be run on a free power supply.
Cooling capability(W) | 45 |
---|---|
Rated Voltage(V) | Single-phase AC100~240 |
Mounting type | Side-mount |
External dimensions(mm) | H262×W234×D175 |
Weight(kg) | 6.5 |
Product Details for NRC-50AL
Specifications
Mount type | Side-mount |
---|---|
cooling method | Electronic cooling system with Peltier element |
Cooling capability (W) | 45 |
Dehumidifying power (g/h) | 38 (normal mode)/46 (Dehumidifier mode) |
Use Area Temperature (°C) | 10~45 |
Use Area Humidity (%RH) | 10~85 (No condensation) |
External dimensions (mm) | H262×W234×D175 |
Weight (kg) | 6.5 |
Coating Color | Y22-85B Ivory or suitable color |
Rated Voltage (V) | Single-phase AC100~240 |
Consumption Current (A) | Rated: 1.45 |
Withstand voltage | 1000V for 1 minute (transformer capacity 500VA) |
Vibration Resistance | 5Hz frequency 20mm total amplitude |
Electric wave regulation | VCCI (Class A compliant) |
Dust prevention / dust proof protection class | Equivalent to IP54 (internal circulation route) |
Noise (dB (A)) | Approx. 56 |
Display | Power lamp (green) |
Note)
Cooling capacity: According to the heater equilibrium formula at an ambient temperature of 25 ℃ and in a measurement booth of size H500×W300×D500.
Current consumption/power consumption: Value at an ambient temperature of 25 ℃, ambient humidity of 40% and panel internal temperature of 25 ℃ and voltage of 100 V.
Permissible ambient temperature: Risk of freezing when operating with no load at an ambient temperature of 10 ℃ or lower.
Dehumidification capacity: Capacity at an ambient temperature of 30 °C and humidity of 80%.
Accessories list
Mounting bolt for main unit | 4 (M5×L20) |
---|---|
Drain hose | 0.5m |
Insulation lock ties | 1 |
Spacer | 4 |
Instruction manual | 1 |
External dimensions
(1) Alarm Output Line : Cord length 2m
Diagram of Panel Cutout (Standard panel cut)
Figure seen from control board outside.
Please keep screw pace on the occasion of processing.
Capacity characteristic chart
Capacity measurement conditions : According to heater balance method.
[Caution]
To ensure proper operation of this equipment, read the operation manual before use.
Depending on model and quantity, separate charter delivery may be arranged (additional costs apply).
Overseas at the time of delivery, we recommend packing for overseas separately.
Using beyond the rated power supply range may cause malfunction.