  5. PAU-GR3000SE-HC

Precision air conditioners (TCU/ECU) PAU-GR3000SE-HC

Precision air conditioners (TCU/ECU)
Temperature and humidity control

PAU-GR3000SE-HC

PAU Series

Precision air conditioners (TCU/ECU) Temperature and humidity control PAU-GR3000SE-HC

Revolutionary compact design and non-freon refrigerant.

  • Air-cooling type
  • Temperature and humidity control
Air outlet volume(m3/min) 10.0(Normal mode)
Cooling capacity(W) 3000 (3500)
Thermal capacity(W) 3400 (1150)
Rated voltage(V) Three-phase, 200 to 240 VAC
Control models Temperature and humidity control
External Dimensions(mm) H1470×W450×D900
Weight(kg) 130

Product Details for PAU-GR3000SE-HC

Specifications

Cooling scheme Air-cooling type
Control models Temperature and humidity control
Cooling capacity(W) *1 3000 (3500)
Thermal capacity(W) *2 3400 (1150)
Humidity capacity(g/㎏(DA)) *3 5.1
Dehumidifying capacity(g/㎏(DA)) *4 12.9 (Attained dew point temperature: 3.5℃ DP or less)
Temperature control precision(℃) *5 ±0.1
Temperature control range(℃) *6 20 to 30
Humidity control precision(%RH) *5 ±0.5
Humidity control range(%RH) *6 35 to 75
Temperature setting range (℃) *7 0 to 50
Humidity control setting range(%) *7 0 to 99.99
Ambient temperature(℃) 15 to 35 (Temperature change gradient: 1℃ or less/h)
Ambient humidity(%RH) 15 to 85 (Humidity change gradient: within 5%RH/1h) (No condensation)
Air outlet volume(m3/min) *8 10.0 (Normal mode / Energy saving mode)
3.0 (Dry mode)
External Dimensions(mm) *9 H1470×W450×D900
Weight(kg) 130
Coating Color Munsell N-87 gray equivalent
Blower duct connection diameter(mm) φ150
Rated voltage(V) *10 Three-phase, 200 to 240 VAC
Current consumption(A) ※11 4.7(Rated) / 6.1(MAX)
Power consumption(W) *11 1180(Rated) / 1460(MAX)
Humidifier / Water supply pressure(MPa) 0.2 to 1.0
Humidifier / Water temperature(℃) (OA - 10℃) to 50
Humidifier / Water supply connection port 8A socket
Drain connection diameter 20A (Rc3/4) ×2P
Frame drain connection port diameter 15A (Rc1/2)
Refrigerant(g) R1234yf 890g
Exhaust air volume(m3/min) *12 10.0
Noise (dB (A)) *13 67
Output/Main unit abnormal output No-voltage (250VAC/2A/resistive load) * Selectable between normally open or normally closed

*1 The heating capacity is 3400 W during normal and energy-saving mode operation, and 1150 W during dry mode operation.
*2 Humidification capacity is based on use with an ambient temperature/humidity of 25℃/50% RH at the end of a 4-meter duct.
*3 "3.5℃ DP or less" is based on use with an ambient temperature/humidity of 27℃/70% RH or 30℃/55% RH during dry mode operation.
*4 Temperature control precision is based on the method prescribed in JTM K01 Constant Temperature and Humidity Chambers - Performance Testing Method and Performance Indication Method (Japan Testing Machine Association).
Only the value indicated by the temperature controller built into the air conditioner at the main unit air outlet is guaranteed to be precise, and thermal interference due to the duct, etc. is not covered by the precision guarantee.
In addition, this product is designed to reduce temperature fluctuations in the air, so the absolute temperature value is not guaranteed. (A bias function for compensation is built into the system.)
*5 Temperature control may not be possible even within the set temperature control range depending on the ambient temperature/humidity.
*6 Control at the set value may not be possible depending on the operating environment.
*7 Use of an auxiliary fan is recommended to secure the blowoff air volume at the duct in situations with significant pressure loss due to a long duct, etc.
*8 Dimensions do not include control panel protrusions, blowout flanges, and casters and their mounting areas.
*9 Use a power supply voltage within ±10% of the rated voltage.
*10 The current consumption and power consumption fluctuate depending on the ambient temperature/humidity and the operating conditions.
*11 Waste heat is discharged from air-cooled systems. (An optional exhaust chamber is available.)
*12 Values measured at a distance of 1 meter from the front of the device

• Refer to the specifications and precautions in the instruction manual during actual installation.
• Use a power supply voltage within ±10% of the rated voltage.
• Please note that product specifications are subject to change without notice.

External dimensions

PAU-GR3000SE-HC External dimensions

Temperature / humidity sensor

PAU-GR3000SE-HC Temperature / humidity sensor

[Caution]
To ensure proper operation of this equipment, read the operation manual before use.
Depending on model and quantity, separate charter delivery may be arranged (additional costs apply).
Overseas at the time of delivery, we recommend packing for overseas separately.
After verifying the specifications, insert an appropriate breaker (circuit breaker for wiring) between the product and power supply.
Cause of failure and be used at the rated power supply out of range.
Please use the service and maintenance on a regular basis.
Failure to maintain regular maintenance, you may be a factor in product performance degradation trouble.
When disposing of this product, you should comply with various laws and regulations, please go to the appropriate.