Precision air conditioners (TCU/ECU) PAU-GRW9000SE-HC
Precision air conditioners (TCU/ECU)
Temperature and humidity control
PAU-GRW9000SE-HC
PAU Series

Revolutionary compact design and non-freon refrigerant.
- Water-cooling type
- Temperature and humidity control
Air outlet volume(m3/min) | 30.0(Normal mode) |
---|---|
Cooling capacity(W) | 9000 (10700) |
Thermal capacity(W) | 9100 (3700) |
Rated voltage(V) | Three-phase, 200 to 240 VAC |
Control models | Temperature and humidity control |
External Dimensions(mm) | H1630×W650×D950 |
Weight(kg) | 210 |
Product Details for PAU-GRW9000SE-HC
Specifications
Cooling scheme | Water-cooling type |
---|---|
Control models | Temperature and humidity control |
Cooling capacity(W) *1 | 9000 (10700) |
Thermal capacity(W) *2 | 9100 (3700) |
Humidity capacity(g/㎏(DA)) *3 | 5.0 |
Dehumidifying capacity(g/㎏(DA)) *4 | 13.0 (Attained dew point temperature: 3.5℃ DP or less) |
Temperature control precision(℃) *5 | ±0.1 |
Temperature control range(℃) *6 | 20 to 30 |
Humidity control precision(%RH) *5 | ±0.5 |
Humidity control range(%RH) *6 | 35 to 75 |
Temperature setting range (℃) *7 | 0 to 50 |
Humidity control setting range(%) *7 | 0 to 99.99 |
Ambient temperature(℃) | 15 to 35 (Temperature change gradient: 1℃ or less/h) |
Ambient humidity(%RH) | 15 to 85 (Humidity change gradient: within 5%RH/1h) (No condensation) |
Air outlet volume(m3/min) *8 | 30.0 (Normal mode / Energy saving mode) 6.0 (Dry mode) |
External Dimensions(mm) *9 | H1630×W650×D950 |
Weight(kg) | 210 |
Coating Color | Munsell N-87 gray equivalent |
Blower duct connection diameter(mm) | φ250 |
Rated voltage(V) *10 | Three-phase, 200 to 240 VAC |
Current consumption(A) ※11 | 13.0(Rated) / 17.4(MAX) |
Power consumption(W) *11 | 3710(Rated) / 5060(MAX) |
Humidifier / Water supply pressure(MPa) | 0.2 to 1.0 |
Humidifier / Water temperature(℃) | (OA - 10℃) to 50 |
Humidifier / Water supply connection port | 8A socket |
Cooling water / Supply water volume(ℓ/min) *12 | 36 |
Cooling water / Supply water pressure(MPa) *12 | 0.75 or less |
Cooling water / Supply water temperature(℃) *12 | (Ambient temperature -10℃) to 35℃ |
Cooling water / Connection diameter *12 | 20A (Rc3/4) |
Drain connection diameter | 20A (Rc3/4) ×2P |
Frame drain connection port diameter | 15A (Rc1/2) |
Refrigerant(g) | R1234yf 2300g |
Noise (dB (A)) *13 | 65 |
Output/Main unit abnormal output | No-voltage (250VAC/2A/resistive load) * Selectable between normally open or normally closed |
*1 Cooling capacity is based on use with an ambient temperature/humidity of 25℃/50% RH at the end of a 4-meter duct.
The cooling capacity in parentheses ( ) is based on use with an ambient temperature/humidity of 30℃/70% RH at the end of a 4-meter duct.
*2 Heating capacity is based on use with an ambient temperature/humidity of 25℃/50% RH at the end of a 4-meter duct during normal and energy-saving mode operation. The heating capacity in parentheses ( ) is based on use with an ambient temperature/humidity of 25℃/50% RH at the end of a 4-meter duct during dry mode operation.
*3 Humidification capacity is based on use with an ambient temperature/humidity of 25℃/50% RH at the end of a 4-meter duct.
*4 "3.5℃ DP or less" is based on use with an ambient temperature/humidity of 27℃/70% RH or 30℃/55% RH during dry mode operation.
Only the value indicated by the temperature controller built into the air conditioner at the main unit air outlet is guaranteed to be precise, and thermal interference due to the duct, etc. is not covered by the precision guarantee.
In addition, this product is designed to reduce temperature fluctuations in the air, so the absolute temperature value is not guaranteed. (A bias function for compensation is built into the system.)
*5 Temperature control precision is based on the method prescribed in JTMK01 Constant Temperature and Humidity Chambers - Performance Testing Method and Performance Indication Method (Japan Testing Machine Association).
Only the value indicated by the temperature controller built into the air conditioner at the main unit air outlet is guaranteed to be precise, and thermal interference due to the duct, etc. is not covered by the precision guarantee. In addition, this product is designed to reduce temperature fluctuations in the air, so the absolute temperature value is not guaranteed. (A bias function for compensation is built into the system.)
*6 Temperature control may not be possible even within the set temperature control range depending on the ambient temperature/humidity.
*7 Control at the set value may not be possible depending on the operating environment.
*8 Use of an auxiliary fan is recommended to secure the blowoff air volume at the duct in situations with significant pressure loss due to a long duct, etc.
*9 Dimensions do not include control panel protrusions, blowout flanges, and casters and their mounting areas.
*10 Use a power supply voltage within ±10% of the rated voltage.
*11 The current consumption and power consumption fluctuate depending on the ambient temperature/humidity and the operating conditions.
*12 Do not use high-purity water or ultrapure water (with a conductivity of 1μS/cm or less and a resistivity of 10 MΩ・cm or more) for water supply to the unit. Cooling water should be supplied while ensuring the water temperature change gradient is no more than 1℃/h and the water volume change gradient is no more than 1ℓ/h.
*13 Values measured at a distance of 1 meter from the front of the device.
• Refer to the specifications and precautions in the instruction manual during actual installation.
• Use a power supply voltage within ±10% of the rated voltage.
• Please note that product specifications are subject to change without notice.
External dimensions
Temperature / humidity sensor
[Caution]
To ensure proper operation of this equipment, read the operation manual before use.
Depending on model and quantity, separate charter delivery may be arranged (additional costs apply).
Overseas at the time of delivery, we recommend packing for overseas separately.
After verifying the specifications, insert an appropriate breaker (circuit breaker for wiring) between the product and power supply.
Cause of failure and be used at the rated power supply out of range.
Please use the service and maintenance on a regular basis.
Failure to maintain regular maintenance, you may be a factor in product performance degradation trouble.
When disposing of this product, you should comply with various laws and regulations, please go to the appropriate.
We're here to give you quick answers to your questions.