1. HOME
  2. Product information
  3. Temperature control equipment Oil chiller VSC series
  4. Oil chillers Product lineup
  5. VSC-5600S

Oil chiller VSC-5600S

Oil chiller
End of Sales Model

VSC-5600S

VSC series

CE
Oil chiller End of Sales Model VSC-5600S

High power model that demonstrates its capabilities in a variety of sites.

Use Area Temperature(℃) 5~50
Cooling capability(W) 5200/5600
Power-supply voltage(V) Three-phase AC200
External dimensions(mm) H1110×W470×D500
Weight(kg) 94

Product Details for VSC-5600S

Specifications

Cooling method Air-cooled type
Cooling capacity(W) 5200/5600
Temperature control range / tuned type(℃) Set standard temperature ±19.9
Temperature control range / fixed type(℃) 5~50
Usable Oil Lubricant, petroleum hydraulic oil (Viscosity:1.4 to 200mm2/s)
Circulating oil pressure / inlet side(kPa) -30.7~0(No fluctuations)
Circulating oil pressure /outlet side(kPa) 0.5 or less(No fluctuations)
Use Area Temperature(℃) 5~50
External dimensions(mm) H1110×W470×D500
Weight(kg) 94
Coating Color Light beige(Munsell No-5Y7.0/1 Semi-gloss)
Power-supply voltage(V) Three-phase AC200
Consumption current(W) 1650/2100
Voltage source capacity(kVA) 4.4
Voltage source capacity(kVA) Rc1/8
Compressor Fully enclosed rotary
Condenser / evaporator Fins & tubes
ファン出力(W) 45×2
Certification CE / ETL
Refrigerant / Type R407C 1150g
Noise(dB (A)) 63
Pump / rated output(W) 700
Pump / Discharge rate(ℓ/min) 30.0/36.0 Relief valve set pressure: 0.6MPa (start)
Pipe connection / Oil outlet Rc11/4
Pipe connection / Oil intlet Rc11/4
Input / output terminals Remote operation / alarm
Protector High pressure switches, overcurrent relays for pumps, overcurrent relays for compressors, compressor internal thermostats, circuit fuses
Overvoltage classification categoryⅢ according to IEC60664-1
Degree of contamination degreeⅢ according to IEC60664-1

*Cooling capacity, current consumption, and power consumption values are based on a 35ºC room temperature and 35ºC oil temperature (ISO VG5).
*Do not use machining fluids, grinding fluids, water and water soluble liquids, pharmaceutical and food product liquids, gasoline, kerosene, thinner and other highly volatile, low-lubricant fluids, or flame-retardant hydraulic oil.

External dimensions

VSC-5600S External dimensions

(1) Operation panel
(2) Filter
(3) legs
(4) Oil piping port (outlet side): RC 3/4
(5) Oil piping port (inlet side): RC 3/4
(6) Oil drain port: RC 1/8
(7) Hanging bracket
(8) Electric wire intake (both sides): For conduit
(9) Air discharge grill (top)
(10) Air discharge grill (rear)
(11) Air discharge grill (both sides)

Capacity characteristic

VSC-5600S Capacity characteristic

[Operating conditions]
(1) Liquid temperature sensor: outlet temperature sensor
(2) Control method: Airframe temperature tuning method
(3) Oil used: ISO VG5

Please use it properly Read the manual before using Delivery of the items will be passed on the car.
(Domestic location specified, except islands) will be (additional cost) Charter flights handled separately by the number, type .
Overseas at the time of delivery, we recommend packing for overseas separately.
After verifying the specifications, insert an appropriate breaker (circuit breaker for wiring) between the product and power supply.
Cause of failure and be used at the rated power supply out of range.
Please use the service and maintenance on a regular basis.
Failure to maintain regular maintenance, you may be a factor in product performance degradation trouble.
When disposing of this product, you should comply with various laws and regulations, please go to the appropriate.