HFC alternative non-drain
ENC-GR810LE-eco
Cooling capacity(W)*1 | 800 |
---|---|
Rated voltage(V) | Single-phase, 100 to 120 VAC |
Mounting Type | Side-mounting |
External Dimensions(mm) | H730×W300×D280 |
Weight(kg) | 28 |
Inquiry
Download
ENC-GR810LE-eco Product details
Specifications
See specification in the catalogue(50/60Hz)
Mounting Type | Side-mounting |
---|---|
Cooling capacity(W)*1 | 800 |
Setting temperature range (℃) | 25~45 |
Ambient temperature(℃) | 20~55 |
Ambient humidity(%RH) | 10~85 (No condensation) |
External Dimensions(mm) | H730×W300×D280 |
Weight(kg) | 28 |
Coating Color | Munsell 5Y 7/1 Equivalent color of light beige |
Rated voltage(V) | Single-phase, 100 to 120 VAC |
Current consumption *3 : Rating(A) *4 | 4.2/4.2 |
Current consumption *3 : Max(A) *5 | 5.5/5.5 |
Power consumption *3 : Rating(W) *4 | 365 |
Power consumption *3 : Max(W) *5 | 470 |
Recommended breaker capacity (A) | 10 |
Vibration resistance | Equivalent to JIS Z0200 Level1 |
Dust and water proof protection rating | Equivalent to IP54 (internal circulation route) |
Certification | CE |
Refrigerant / Amount(g) | R1234yf 190g |
Noise (dB(A)) | 約74 |
External output | Alarm output (non-voltage a contact: 250V 2A resistive load) can be switched to non-voltage b contact by setting |
Display | Panel temperature/Error/RUN |
* cooling capacity: Ambient temperature 35°C, humidity 40%RH, power-supply voltage values at 200V (100V models only) rating capacity values at 100V. (Measurement conditions: JIS B 8615-1 indoor side air enthalpy test method)
Use Area Temperature / use area Humidity define the operating range and do not guarantee rating performance.
* rating values: Ambient temperature 35°C and humidity 40%RH, power-supply voltage at 200V (100V models only) rating values at 100V.
*MAX value: The ambient temperature at the MAX value is specified respectively.
*Use power-supply voltage within ±10% of rated voltage.
current consumption and power consumption are the values in cooling operation.
*Dustproof and drip-proof protection grade: except drain pipe part
Please read the instruction manual carefully before use to ensure correct operation.
*Compared under the following conditions: ambient temperature 35°C, set temperature in the board 35°C, power supply frequency 60 Hz, load in the board 450 W,
The former model ENC-G810LE power consumption is 386W and ENC-GR810LE-eco is 186W, which is superior in productivity.
External dimensions
Diagram of Panel Cutout
Capacity characteristic chart
*Contact our sales representative if you are using the control panel cooler in an environment close to the permissible ambient temperature upper limit.
[Caution]
To ensure proper operation of this equipment, read the operation manual before use.
Depending on model and quantity, separate charter delivery may be arranged (additional costs apply).
Overseas at the time of delivery, we recommend packing for overseas separately.
Please check through the cooler between the FA and the power (circuit breakers) to the appropriate specification of the FA breaker cooler.
Cause of failure and be used at the rated power supply out of range.
Please use the service and maintenance on a regular basis.
Failure to maintain regular maintenance, you may be a factor in product performance degradation trouble.
When the outside temperature is low in winter, please do not let the FA cooler continuous operation.
When disposing of this product, you should comply with various laws and regulations, please go to the appropriate.