1. HOME
  2. Product information
  3. Environmental equipment Dust Collector GDE Series
  4. Dust Collector Product lineup
  5. GDE-A2200

Dust Collector Details GDE-A2200

Dust Collector
High-performance dust collector

GDE-A2200

GDE Series

Dust Collector High-performance dust collector GDE-A2200

Fan motor performance characteristics curve

Collection method Filter method
Clearing method Green pulse method
Blower motor output(kW) 2.2
Air flow(m3/min) 15/30/35
External dimensions(mm) H1698×W770×D770
Weight(kg) 260

Product Details for GDE-A2200

Specifications

Specifications Standard model
Fan motor(kW) 2.2
Air flow(m3/min) 15/30/35
Fan static pressure(kPa) 3.09/2.86/2.60
External static pressure(kPa) 2.91/2.16/1.67
Frequency adjustment range(Hz) 20~60
Operating temperature(℃) 40 or less (No condensation)
Suction gas temperature(℃) 40 or less (No condensation)
Clearing method Green pulse method
Used compressed air pressure(MPa) 0.5
Standard air consumption(L/min [N.T.P]) 25
External dimensions(mm) H1698×W770×D770
Weight(kg) 260
Suction opening dimensions(φmm) 198
Coating color Coating color main unit: JPMA N-75 Panels: JPMA N-35
Rated voltage(V) Three-phase AC200V (50Hz/60Hz)or 220V (60Hz)
Power supply wire gauge □2
Recommended breaker amperage(A) 30
Max. input current(A) * 11.0
Max. Power consumption(kW) * 2.8
Component / Fan Turbo fan
Component / Motor IE3 Vertical fl ange motor
Component / Main filter Area(m2) 36
Component / Ultra-fine filter ・ Count (Unit) 6
Component / Integrated pilot valve (Unit) 2
Component / Dust box ・ capacity (L×Unit) 17×2(resin)
Component / Caster (φmm×Unit) 75×4
Display type Touch-panel
Control output / Alarm output Arbeit contact Non-voltage (Voltage:DC30V/AC220V or lessMaximum load:2A or less (Resistive load) /80VA(Inductive load))
Control output / Caution output Arbeit contact Non-voltage (Voltage:DC30V/AC220V or lessMaximum load:2A or less (Resistive load) /80VA(Inductive load))
Control output / Operation output Arbeit contact Non-voltage (Voltage:DC30V/AC220V or lessMaximum load:2A or less (Resistive load) /80VA(Inductive load))
Control input / Operation, stop input Non-voltage input
Control input / Pulse disabled Non-voltage input
Control input / Pulse running Non-voltage input
Noise(dB[A]) 67±2

* Measured at 60 Hz operation when new and without duct installation. Value may vary depending on operating conditions.

External dimensions

GDE-A2200 External dimensions

Fan motor performance characteristics curve

GDE-A2200 Fan motor performance characteristics curve