What is an inverter chiller?
Apiste’s inverter chillers use an independently developed inverter to control the compressor, fan motor, and pump, allowing for optimal cooling at all times in response to load fluctuations and changes in the operating environment.
Furthermore, our unique IOF sensing constantly measures the inlet temperature, outlet temperature, and flow rate, allowing us to grasp load and flow rate fluctuations that occur in the production process faster and more accurately than any other chiller. This achieves energy savings through optimal operation according to the equipment’s status.
Suitable for the following customers
- I want to reduce CO2 emissions from my factory.
- Want to reduce the running costs of equipment
| Model | Cooling capacity (W) |
Heating capacity (W) |
Circulating water temperature range (°C) |
Temperature control precision (°C) |
External dimensions (HxWxD) (mm) |
||
|---|---|---|---|---|---|---|---|
| Air-cooling PCU-SL10000 |
10300/10300 | 2500 | 5~45 | ±0.1 | 1468×850×750 |
Catalog Manual |
|
| Air-cooling PCU-SL14000 |
13300/13300 | 2500 | 5~45 | ±0.1 | 1496×850×750 |
Catalog Manual |
|
| Water-cooling PCU-SL12000W |
12000/12000 | 2500 | 5~45 | ±0.1 | 1349×850×750 |
Catalog Manual |
|
| Water-cooling PCU-SL15000W |
14200/14200 | 2500 | 5~45 | ±0.1 | 1349×850×750 |
Catalog Manual |
Select a chiller based on its features
Product Category
The PCU-NE series is a new chiller that is the first in the industry to use HFC-alternative refrigerants and also comes equipped with two industry-first features: a drive recorder and a time calendar.
Highly durable, energy-saving chiller
This chiller combines high energy-saving performance of up to 50% with durability that can withstand harsh field environment and outdoor use. It also has high-temperature precision and is suitable for a variety of applications.
Wide range High stability Chiller
Controls circulating water over wide range of -10°C to 80°C and with a high precision of ±0.05°C. Widely used in manufacturing, development, and research fields.
HFC alternative pump/tankless chiller
The PCU-F series has a structure that does not have a pump or tank inside the main body. This structure greatly improves design freedom and allows for flexible response to a variety of needs.
If you are having trouble selecting a product or would like to discuss implementation,
Please feel free to contact us.
People who viewed this page also checked out these documents:
Inquiry
For product inquiries, quote requests, etc.
Please feel free to contact us.