  3. Heat-control equipment control panel cooling unit ENC Series
  4. Model list
  5. ENC-AR1120L-SUS-2
control panel cooling unit Freon special specification ENC-AR1120L-SUS-2

Fluorocarbon special specification
ENC-AR1120L-SUS-2

Cooling capacity(W)*1 950/1100
Rated voltage(V) Single-phase 200V AC
Mounting Type Side-mounting
External Dimensions(mm) H730×W300×D230
Weight(kg) 24

ENC-AR1120L-SUS-2 Product details

(50/60Hz)

Mounting Type Side-mounting
Cooling capacity(W)*1 950/1100
Setting temperature range (℃) 25~45
Ambient temperature(℃) 20 to 50
Ambient humidity(%RH) 10~85 (No condensation)
External Dimensions(mm) H730×W300×D230
Weight(kg) 24
Surface Finish NSSC 180-HL finish
Rated voltage(V) Single-phase 200V AC
Current consumption *3 : Rating(A) *4 2.6/2.4
Current consumption *3 : Max(A) *5 3.1/3.2
Starting current (A) 7.5/7.1
Power consumption *3 : Rating(W) *4 440/460
Power consumption *3 : Max(W) *5 560/570
Noise resistance Fast transient/burst immunity test level 4
Vibration resistance Equivalent to JIS Z 0200 Level1
Dust and water proof protection rating Equivalent to IP54 (internal circulation route)
Refrigerant / Amount(g) R134a 230g
Noise (dB(A)) Approximately 64/68
External output Cooling operation output/ alarm output (non-voltage a contact: 250V 2A resistive load)
Display Panel temperature display LED/RUN LED

Note)
cooling capacity: rating capacity value when outside temperature is 35°C and internal temperature is set to 35°C. (Measurement conditions: JIS-C-9612 air enthalpy method)
Use Area Temperature and humidity conditions for use area Humidity are not guaranteed to be met.
rating: Value when Use Area Temperature 35°C and use area Humidity 40% RH.
MAX value: The value when Use Area Temperature is the maximum allowable ambient temperature and use area Humidity is 40% RH.
- Use power-supply voltage within ±10% of rated voltage.
- Be sure to read the instruction manual carefully before use and use it correctly.

External dimensions

ENC-AR1120L-SUS-2 Dimensions

power supply line: Cord outside length 3m
alarm output line: Cord length outside the machine: 3m

Diagram of Panel Cutout

ENC-AR1120L-SUS-2 installation diagram

Capacity characteristics graph

ENC-AR1120L-SUS-2 capacity characteristics graph

*If you plan to use the FA cooler in environment close to the upper limit of the allowable ambient temperature, please consult with our sales representative.

[Caution]
To ensure proper operation of this equipment, read the operation manual before use.
Depending on model and quantity, separate charter delivery may be arranged (additional costs apply).
Overseas at the time of delivery, we recommend packing for overseas separately.
Please check through the cooler between the FA and the power (circuit breakers) to the appropriate specification of the FA breaker cooler.
Cause of failure and be used at the rated power supply out of range.
Please use the service and maintenance on a regular basis.
Failure to maintain regular maintenance, you may be a factor in product performance degradation trouble.
When the outside temperature is low in winter, please do not let the FA cooler continuous operation.
When disposing of this product, you should comply with various laws and regulations, please go to the appropriate.

Inquiry

For product inquiries, quote requests, etc.
Please feel free to contact us.

TEL: 0120-945-354

This service is not available from some IP phones.

support@apiste.co.jp